12-circuit transmitting output color screen paperless recorder

1 sku

12-circuit transmitting output color screen paperless recorder

Technical parameters

1. Full isolation universal input: HHG-70R series of instruments allows direct input of 40 different types of signals. It has full isolation between channels, and the isolation voltage is greater than 400V;
2. Output signal: Power distribution: 16-circuit power distribution, 8 sets of 24VDC output, output current 60mA / group;
3. Communication Interface: RS-232C, RS-485 and Ethernet RJ45;
4. Transmission output: no requirements, 4-circuit transmitter output, 8--circuit transmitter output, 12--circuit transmitter output

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
No fixed device type on-site temperature display

1 sku

No fixed device type on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
SFJ-B Deepth and weight indicator

1 sku

SFJ-B Deepth and weight indicator

Technical parameters


Executive standard

Q/JMD16-2016, Q/JMD05-2015

Supply capability

Brand : MIND

Guarantee period : 12 Months

Inquiry Now
Portable Water Pressure Calibration Console

1 sku

Portable Water Pressure Calibration Console

Technical parameters

1. Pressure range: 0-60MPa
2. Tuning sensitivity: min 1kpa
3. Media: clean transformer oil
4. Overall dimensions: 400*410*180 (L*W*H)
5. Weight: 6kg

Executive standard

Enterprise standard

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
Movable sleeve flange type on-site temperature display

1 sku

Movable sleeve flange type on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
Color screen paperless recorder

1 sku

Color screen paperless recorder

Technical parameters

1. Full isolation universal input: HHG-70R series of instruments allows direct input of 40 different types of signals. It has full isolation between channels, and the isolation voltage is greater than 400V;
2. Output signal: Power distribution: 16-circuit power distribution, 8 sets of 24VDC output, output current 60mA / group;
3. Communication Interface: RS-232C, RS-485 and Ethernet RJ45;
4. Transmission output: no requirements, 4-circuit transmitter output, 8--circuit transmitter output, 12--circuit transmitter output

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
Time Depth Recorder

1 sku

Time Depth Recorder

Technical parameters

1. Operating temperature: 0-+50ºC.
2. LDC: vision field 122 mm x 92 mm, 320 x 240 pixed, monochrome.
3. Control: used to input parameters and function selection, LCD backlight switch, and power switch.
4. State LED: green LED displaying and measuring acquisition state while red LED for alarm and erasure and other purposes.
5. Clock: logging real time clock.
6. Memorizer: 16 MB non-volatile type, capable of recording 920 h depth data or depth and all 8 analog channel data for 320 h.
7. Communication interface: RS232 serial communication, Baud rate optional, 9.6 bps, 19.2 bps, 38.4 bps.
8. Power supply: 4 built in D-type batteries/externally connected 12-24 VDC/externally connected 100-250 VAC.
9. Depth interface: 5 V, 12 V, receiving orthogonal depth signals.

Executive standard

Q/WS 001-2015

Supply capability

Brand : WELL-SUN

Guarantee period : 12 Months from the date of delivery

Inquiry Now
Fixed sleeve threaded on-site temperature display

1 sku

Fixed sleeve threaded on-site temperature display

Technical parameters

1. Accuracy: ± 1.0% F.S
2. Header accuracy: ± 0.5% F.S, ± 0.2% F.S
3. Stability: better than ± 0.2F.S / year
4. Resolution: 0.1 for <200 and 1 for> 200
5 Start-up time: within 10s after power on
6. Display: 3 and a half LCD
7. Power: Lithium battery section
8. Power consumption: HHG-PC 10 months, 1.5mW level
9. Protection class: better than IP65
10. Installation: no fixed device type,, fixed sleeve threaded type, removable sleeve threaded type,, fixed sleeve flange type,, removable sleeve flange type,

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Inquiry Now
KB2100Ⅱ gas alarm controller

1 sku

KB2100Ⅱ gas alarm controller

Technical parameters

1. Working voltage: AC220±15% 50Hz±1%.
2. Power consumption: ≤5W/ circuit.
3. Matched detector: Detectors with standard 4~20mA output.
4. Environmental conditions: Temperature: -10℃~50℃; Humidity: <95%RH no condensation.
5. Indication way: Concentration data display through LED.
6. Alarm way: Alarm by LED lamp or audible and visual alarm of status.
7. Output signal: Digital quantity: RS485 (standard); Analog quantity: 4~20mA (optional).
8. Contact output: Normally opened for low alarm, normally opened for high alarm, normally opened for fault alarm.
9. Installation way: Wall-mounted type, cabinet type.
10. Requirements for connecting cable of detector and controller: ≥RVVP3×1.5mm2.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Inquiry Now
KB9000 gas alarm controller

1 sku

KB9000 gas alarm controller

Technical parameters

1. Power supply: Main power supply: AC 220V±33V 50Hz±5Hz; Emergency power supply: DC 24V±3V rechargeable lead-acid battery.
2. Supply voltage output: DC 24V±6V.
3. Channel of analog detector: 16-channel 4~20mA.
4. Channel of digital detector: 2-channel (RS485), each channel can connect 32 detectors.
5. Digital uploading channel: 1-channel (RS485), supported protocols MODBUS, TC200, Aoruina.
6. Output power of analog detector: Voltage: 27V±3V, protective current of each circuit ≤0.5A.
7. Output power of digital detector: Voltage: 27V±3V, protective current of each circuit ≤2.5A.
8. Total output protective current: ≤5A.
9. Passive relay output: 6 circuits.
10. Relay contact capacity: ≤5A.
11. Operating humidity: ≤95%RH.
12. Display mode: audible (≥85dB), visual alarm.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months after leaving factory

Inquiry Now