Product characteristics

flow (m³/h)
plunger diameter (mm)
rated pressure
dimension (mm)
chassis model
emission standard
material
weight (kg)
boundary dimension (mm)
boundary dimension(mm)
explosive-proof grade
flow coefficient
plunger stroke (mm)
70
rated flow (l/min)
speed (min-¹)
appearance dimension (mm)
power(kw)
protection grade
specification
water tank volume (m³)
Image fire detector

1 sku

Image fire detector

Technical parameters

1. 1920*1080 pixels, min. illuminance is OLux F1.4;0.0002Lux F1.2(DAY), aperture control DC/Video;
2. Fire response time: Flame detection 5-10S, detection delay 10-20S;
3. Sensitivity range: Flame detection is no less than 0.1m², gasoline fire detection range is 150m, and smoke detection is no less than 3% image height;
4. Lens focal length is 12mm, relay output is fire alarm and failure, network output is TCP/IP 10/100M bit/s, power input is DC+12V-+10%/AC220V-+10%, power consumption is 8.0W, and operating temperature is -20-70℃.

Executive standard

GB15631

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Inquiry Now
Exlposion-Proof Buzzer

2 sku

Exlposion-Proof Buzzer

Technical parameters

1. Specifications:CZ 0205 MA100/1;
2. Voltage:AC220/380;
3. Applicable temperature:-40℃~+55℃;
4. Rated Current:16A.

Executive standard

GB3836.1-2010; GB3836.2-2010; GB3836.3-2010; GB3836.4-2010; GB3836.9-2010; GB12476.1-2000; IEC 60079-0:2011; IEC 60079-1:2014; IEC 60079-7:2015; IEC 60079-11:2011; IEC 60079-18:2014; IEC 60079-31:2013; EN 60079-0:2012; EN 60079-1:2014; EN 60079-7:2015; EN 60079-11:2012; EN 60079-18:2015; EN 60079-31:2014

Supply capability

Brand : CZ

Guarantee period : 36 Months

Inquiry Now
Airport fire truck

1 sku

Airport fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Model of chassis: Benz Actros3348;
3. Boundary dimension: 10,065x2,500x3,980mm;
4. Power: 350kW;
5. Water filling amount: 9,000kg;
6. Foam filling amount: 1,000kg;
7. Jet range of fire monitor: foam≥75m, water≥85m;
8. Flow of fire monitor: 100L/s.

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Inquiry Now
GT-WD2200 series spot type gas detector

1 sku

GT-WD2200 series spot type gas detector

Technical parameters

1. Gas to be detected: flammable gas, poisonous gas, oxygen.
2. Detection principle: catalytic combustion type, geochemistry type, semiconductor type, infrared sensor, photoionization type.
3. Detection method: natural proliferation
4. Working voltage: DC24V±6V
5. Detection accuracy: ≤±3%F.S (flammable)
6. Status indication: yellow LED refers to fault; red refers to concentration alarm; green refers to normal working.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 moths after delivery

Inquiry Now
DNCZJ50/70 Drilling Rig Fire Station

1 sku

DNCZJ50/70 Drilling Rig Fire Station

Technical parameters

1. Dimension: 11,900 x 2,980 x 3,100 mm;
2. Skid size: 11,900 x 2,980 x 388 mm;
3. Water tank volume: 32 m³;
4. Foam tank volume: `.64 m³;
5. Motor pump flow: 35 L/s;
6. Motor pump head: 130 m;
7. Diesel pump flow: 35 L/s;
8. Diesel pump head: 70-120 m.

Executive standard

1. GB7956.1 Fire Engine Part I: General Technical Conditions; 2. GB20031-2005 General Conditions of Foam, Fire Extinguishing Systems, and Components; 3. GB/T 700 Carbon Structural Steel; 4. JB/T 4735 Steel Welding Pressure Vessel; 5. HG/T 20592-20635-2009 Steel Pipe Flanges, Gaskets, and Fasteners; 6. Q/SYBOMCO J075 Steel Structure Welding Code; 7. Q/SYBOMCO J078-2010 General Specification for Paint Painting; 8. NFPA 16-2007 Foam Sprinkler and Foam Sprinkler System Installation Standards.

Supply capability

Brand : YINHE

Guarantee period : 12 months from the date of delivery

Inquiry Now
OPGD1000 open-circuit detector

1 sku

OPGD1000 open-circuit detector

Technical parameters

1, Testing gas: methane, hydrogen sulfide.
2, Detection principle: laser absorption spectrum.
3, The detection range: 0 ~ 2000ppm · m / 0 ~ 1LEL · m (CH4); 0 ~ 1000ppm · m / 0 ~ 5000ppm · m (H2S).
4, The working distance: 0 ~ 60m; 0 ~ 120m; 0 ~ 220m (optional).
5, Response time: T90 <3s.
6, The environmental conditions: temperature: -40 ℃ ~ 70 ℃; humidity: 0 ~ 95% RH (no condensation).
7, The output signal: 4 ~ 20mA; RS485.

Executive standard

GB-15322 1-2003 GB-12358 - 2006

Supply capability

Brand : Hanwei

Guarantee period : 12 months from the date delivery

Inquiry Now
Positive/negative smoke-exhausting fire truck

1 sku

Positive/negative smoke-exhausting fire truck

Technical parameters

1. Emission standard: GIV and GV (optional);
2. Chassis model: Germany MAN TGS 33.480;
3. Boundary dimension: 9,680x2,500x3,950mm;
4. Power of smoke draft fan: ≥162kW;
5. Water filling amount: 2,000kg;
6. Positive pressure whole air/smoke exhausting capacity: 800,000m³/h;
7. Positive pressure whole air exhausting distance: ≥80m (windness, or with helping wind) .

Executive standard

GB 7956.1-2014

Supply capability

Brand : YINHE

Guarantee period : Within 12 months upon the delivery date

Inquiry Now
3GQ2B high-pressure washer (55KW)

5 sku

3GQ2B high-pressure washer (55KW)

Technical parameters

1. Speed (min-¹): 375;
2. Plunger stroke (mm): 70;
4. Rated pressure (Mpa): 22-70;
5. Flow (m³/h): 2.3-7.5;
6. Plunger diameter (mm): 25-45.

Executive standard

Corporate Standard

Supply capability

Brand : JET

Guarantee period : for 12 months after delivery

Inquiry Now
IG541 mixed gas fire extinguishing system

2 sku

IG541 mixed gas fire extinguishing system

Technical parameters

1. System design nominal pressure: 17.2Mpa;
2. Max. system operating pressure (50℃): 17.2MPa;
3. Container filling pressure (20℃): 15MPa;
4. System min. operating pressure (0℃): 13.6MPa;
5. Storage container capacity: 80L and 90L;
6. Storage filling weight: 211.15Kg/m3;
7. Extinguisher discharge time ≤60s;
8. Storage temperature: 0-50℃;
9. Startup gas: Nitrogen;
10. Startup cylinder filling pressure: 6MPa

Executive standard

GB25972-2010

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Inquiry Now
Water mist fire extinguishing device

6 sku

Water mist fire extinguishing device

Technical parameters

There're open nozzles and anti-error spray nozzles, the operating pressure of open nozzle is 1.4-2.5Mpa, while the operating pressure of anti-error spray nozzle is 1.6-2.5Mpa.

Executive standard

GB50898-2013 Water Mist Fire Extinguishing System Technical Specification

Supply capability

Brand : Sureland

Guarantee period : 18 months since signing of the contract and 12 months since arrival and acceptance on site, while the priority is given to the first satisfaction of time.

Inquiry Now