Product characteristics

scale range (mpa)
nominal diameter (mm)
joint thread
scale range (kpa)
accuracy class
nominal pressure (mpa)
connection method
shell material
instrument diameter (mm)
negative pressure (kpa)
positive and negative pressure (kpa)
positive pressure (kpa)
control form
connector material
range ratio
caliber
dial diameter (mm)
electrode material
installation way
accuracy
YCSAN Dual Diaphragm HHP Shock-proof Differential Pressure Gauge

2 sku

YCSAN Dual Diaphragm HHP Shock-proof Differential Pressure Gauge

Technical parameters

1. Case: 100, 150mm;
2. Precision: ±1.6%,±2.5%, optional;
3. Case material: SUS304.
4. Indicator dial: aluminum, black characters on a white background.
5. Range: 16~2500KPa, customized.
6. Max. hydrostatic pressure: dually 10MPa.
7. Filled fluid: silicone oil (default), glycerin, fluorinated oil, or propylene glycol for option.

Executive standard

GB/T1226-2010

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
Miniature digital multimeter

1 sku

Miniature digital multimeter

Technical parameters

/

Executive standard

/

Supply capability

Brand : SHEFFIELD

Guarantee period : /

Enquiry Now
Test Pile

1 sku

Test Pile

Technical parameters

Size: 108*4*3000mm.

Executive standard

General atlas of oil and gas pipeline line identifications.

Supply capability

Brand : Like

Guarantee period : 12 months

Enquiry Now
High-purity Zinc Reference Electrode Φ50×260mm

1 sku

High-purity Zinc Reference Electrode Φ50×260mm

Technical parameters

1. Critical current density :+38~-10uA/cm2;
2. Potential accuracy: ≤±60mV;
3. Electrode design life: according to requirements;
4. Open circuit potential: -940 mV(vs,SHE).

Executive standard

GB/T467-1997

Supply capability

Brand : Like

Guarantee period : 12 months

Enquiry Now
Smart Potentiostat 24V500A

1 sku

Smart Potentiostat 24V500A

Technical parameters

1. Operating voltage: AC220V±10%;
2. Input: 3-circuit voltage input and 1-circuit current input, optoelectronic isolation;
3. Input voltage collection accuracy: 10 bits A/D;
4. Analog output: 1-circuit voltage output, output range of 0-2.5v, photoelectric isolation;
5. Current remote transmission: convert to 4 ~ 20mA standard industrial signal, conversion accuracy: 0.5%;
6. Voltage remote transmission: convert to 4 ~ 20mA standard industrial signal, conversion accuracy: 0.5%;
7. Isolation and voltage withstand capacity: DC500V at standard industrial interface;
8. Pipe-to-soil potential input range: 0 ~ 2.000V;
9. Reference input impedance: ≥2MΩ;
10. Display screen: 128 x 64, graphic dot matrix LCD;
11. Button: 6 keys;
12. Working temperature: -25℃-+75℃;
13. Storage temperature: -30℃-+85℃;
14. Communication interface: one standard RS485 (using MODBUS protocol) interface;
15. Record storage: 32Kbytes EEPROM, data saving for 10 years;
16. Program storage area: 64K FLASH.

Executive standard

GB4208

Supply capability

Brand : Like

Guarantee period : 12 months

Enquiry Now
1.6MPa Electromagnetic Flowmeter

1 sku

1.6MPa Electromagnetic Flowmeter

Technical parameters

1. Diameter scope (mm): DN15~1800;
2. Velocity range (m∕s): 0.5~10;
3. Measurement accuracy: ±0.5%;
4. Medium temperature (℃): -25~+150;
5. Level of protection: IP65.

Executive standard

Enterprise standard

Supply capability

Brand : HENGHE

Guarantee period : 12 months after the ex-warehouse date

Enquiry Now
vortex precession flowmeter

3 sku

vortex precession flowmeter

Technical parameters

1. Caliber: DN15 ~ DN400;
2. Accuracy: ±0.5%,±1.0%;
3. Protection grade: IP67;
4, medium temperature: - 50 ~ 280 ℃;
5. Explosion-proof degree: intrinsic safety and explosion isolation;
6. Pressure level: PN16-100, CL150-900;
7. Communication: HART,PROFIBUS PA,FOUNDATION,Fieldbus;
8. Converter form: one-piece, split type.

Executive standard

Q/SYFSB 0006-2017

Supply capability

Brand : FISHERMETER

Guarantee period : 1 year after production

Enquiry Now
Remote Diaphragm Gas Meter

6 sku

Remote Diaphragm Gas Meter

Technical parameters

Nominal Flow Rate:1.6-4 m³/h;
Max. Flow Rate: 2.5-6 m³/h;
Min.Flow Rate: 0.016-0.040 m³/h;
Total Pressure Loss: ≤200Pa;
Operation Pressure Range: 0.5-30kpa;
Operation Ambient Temperature: -10~+40℃;
Connection Thread: M30X2 or Customization.

Executive standard

EN1359

Supply capability

Brand : BETA

Guarantee period : 12 Months

Enquiry Now
Magnetic Flow Meter

1 sku

Magnetic Flow Meter

Technical parameters

1. Nominal diameter: DN100;
2. Nominal pressure: 1.6Mpa;
3. IP code: IP68.

Executive standard

GB/T 9119-2010

Supply capability

Brand : YINUO

Guarantee period : 6 Months

Enquiry Now
Y-150 Series General Pressure Gauge

24 sku

Y-150 Series General Pressure Gauge

Technical parameters

1. Scale scope (MPa): -0.1~100;
2. Accuracy class: 1.5 and 2.5;
3. Ambient temperature: -40~70℃, relative humidity no greater than 85%;
4. Temperature effect: When the service temperature deviates 20 ± 5 ℃, no greater than 0.4%/10 ℃.

Executive standard

Company standard

Supply capability

Brand : CAHE

Guarantee period : 12 months from the date of delivery

Enquiry Now