Product characteristics

nominal cross-sectional area (mm2)
rated voltage (kv)
number of cores
outer diameter of cable (mm)
way to install
protection level
conductor sectional area (mm3)
heat resistance (℃)
length (m/pc)
number of conductors/diameter (n/d)
wire gauge (#)
5
7
4
1
6
2
luminous flux (lm)
rated power (w)
specification (mm2)
anti-corrosion class
lamp power
light source
rated voltage (uo/ukv)
explosion-proof sign
rated voltage (v)
BLK52 explosion-proof circuit breaker

1 sku

BLK52 explosion-proof circuit breaker

Technical parameters

1. Rated voltage: 220V, 380V;
2. Tripping current: 1A~630A;
3. Explosion-proof sign: Exde II BT6, Exde II CT6;
4. Cable outer diameter: 14-50 mm.

Executive standard

GB3836-2000 IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Single-core Copper 3.6-6KV Cross-linked Polyethylene Insulated Non-magnetic Metal Wire Armored PVC Sheathed Power Cable

2 sku

Single-core Copper 3.6-6KV Cross-linked Polyethylene Insulated Non-magnetic Metal Wire Armored PVC Sheathed Power Cable

Technical parameters

1. The product is applicable to medium and high voltage power transmission and distribution system with rated voltage as 3.6/6~26/35kV.
2. The highest rated temperature of cable conductor is 90℃.
3. The highest temperature of short circuited (lasting for maximum 5s) cable conductor shall not exceed 250℃. If the temperature is lower than 0℃, the cable conductor should be preheated first.
4. Minimum bending radius of cable in installation: unarmored single-core cable 20D, unarmored three-core cable 15D, armored single-core cable 15D, armored three-core cable 12D.

Executive standard

Q/320481SSO 32-2015

Supply capability

Brand : SHANGSHANG

Guarantee period : One year from the date of delivery

Enquiry Now
Single-core Copper 3.6-6KV Cross-linked Polyethylene Insulated PVC Sheathed Power Cable

2 sku

Single-core Copper 3.6-6KV Cross-linked Polyethylene Insulated PVC Sheathed Power Cable

Technical parameters

1. The product is applicable to medium and high voltage power transmission and distribution system with rated voltage as 3.6/6~26/35kV.
2. The highest rated temperature of cable conductor is 90℃.
3. The highest temperature of short circuited (lasting for maximum 5s) cable conductor shall not exceed 250℃. If the temperature is lower than 0℃, the cable conductor should be preheated first.
4. Minimum bending radius of cable in installation: unarmored single-core cable 20D, unarmored three-core cable 15D, armored single-core cable 15D, armored three-core cable 12D.

Executive standard

Q/320481SSO 32-2015

Supply capability

Brand : SHANGSHANG

Guarantee period : One year from the date of delivery

Enquiry Now
NSC9720 Anti-glaze Passage Light

4 sku

NSC9720 Anti-glaze Passage Light

Technical parameters

1. Rated voltage: 220VAC 50Hz
2. Shell protection: IP65
3. Insulation grade: I
4. Corrosion-proof level: WF2;
5. Cable: φ6~φ8mm
6. Space-depth ratio: 2.2.

Executive standard

GB3836.1-2010; GB7000.1;

Supply capability

Brand : OKTECH

Guarantee period : 12 months from the date of delivery

Enquiry Now
Single-core Copper 0.6-1KV PVC Insulated PVC Sheathed Power Cable

2 sku

Single-core Copper 0.6-1KV PVC Insulated PVC Sheathed Power Cable

Technical parameters

1. Rated voltage 0.6/1KV;
2. Maximum temperature of cable conductor: 70℃ for PVC insulated, 90℃ for cross-linked polyethylene insulated;
3. The maximum temperature of cable conductor during short-circuit (maximum duration no more than 5S) shall not exceed: PVC insulated conductor cross-section ≤300mm2, 160°C, PVC insulated conductor cross-section> 300mm2, 140°C; Cross-linked Polyethylene insulation 250 °C;
4. Laying temperature of cables: The laying temperature of cables with PVC insulation or sheath shall not be lower than 0°C;
5. Allowable bending radius for cable installation:
Single-core cable non-armored R=20D, armored R=15D
Multi-core cable non-armored R=15D, armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
Single-core Copper 8.7/15KV Cross-linked Polyethylene Insulated Steel Strip Armored PVC Sheathed Power Cable

2 sku

Single-core Copper 8.7/15KV Cross-linked Polyethylene Insulated Steel Strip Armored PVC Sheathed Power Cable

Technical parameters

1. The maximum rated operating temperature of the cable conductor is 90°C;
2. The maximum operating temperature of the cable conductor does not exceed 250°C in short-circuit (maximum duration within 5s);
3. The ambient temperature during cable laying shall be no lower than 0°C. If it is laid below 0°C, it must be warmed in advance;
4. Allowable bending radius for cable installation:
Single core cable: not armored R=20D and armored R=15D; multi-core cable: not armored R=15D and armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
Single-core Aluminum 12/20kV Cross-linked Polyethylene Insulated Polyethylene Sheathed Power Cable

2 sku

Single-core Aluminum 12/20kV Cross-linked Polyethylene Insulated Polyethylene Sheathed Power Cable

Technical parameters

1. The maximum rated operating temperature of the cable conductor is 90°C;
2. The maximum operating temperature of the cable conductor does not exceed 250°C in short-circuit (maximum duration within 5s);
3. The ambient temperature during cable laying shall be no lower than 0°C. If it is laid below 0°C, it must be warmed in advance;
4. Allowable bending radius for cable installation:
Single core cable: not armored R=20D and armored R=15D; multi-core cable: not armored R=15D and armored R=12D
R: minimum bending radius, D: cable outside diameter,

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
NGC9810/NGC9810A Dome Light

4 sku

NGC9810/NGC9810A Dome Light

Technical parameters

1. Rated voltage: 220VAC 50Hz
2. Shell protection: IP65
3. Insulation grade: I
4. Corrosion-proof level: WF2;
5. Inlet thread: G3/4
6. Cable: φ8~φ14mm;
6. Space-depth ratio: NGC9810: 2.9 NGC9810A 1.4.

Executive standard

GB3836.1-2010; GB7000.1;

Supply capability

Brand : OKTECH

Guarantee period : 12 months from the date of delivery

Enquiry Now
ZB2 BA3C Reset Button

1 sku

ZB2 BA3C Reset Button

Technical parameters

1. Equipment: PS165/3150 disc brake.

Executive standard

SY/T6727-2014

Supply capability

Brand : PSK

Guarantee period : Quality guarantee within 12 months from the date of delivery

Enquiry Now
CBP58 Explosion-proof Control Box (IIB, IIC, tD)

1 sku

CBP58 Explosion-proof Control Box (IIB, IIC, tD)

Technical parameters

1. Explosion-proof sign: Ex dllBT6 Gb Ex dllCT6 Gb Gb/ExTD A21 IP65 T80℃,
2. Rated voltage: AC 220/380V
3. Rated current: 100A.
4. Corrosion-proof level: WF1

Executive standard

GB/T 3836.1 GB/T 3836.2 GB/T 3836.3 GB/T 12476.1 IEC60079

Supply capability

Brand : CNYA

Guarantee period : 60 months from the date of delivery

Enquiry Now