WR J Sheathed Thermocouple

4 sku

WR J Sheathed Thermocouple

Technical parameters

1. Insulation: ceramic or ore quality insulation;
2. Structure type: single, double or several temperature sensing elements
3. Measuring range: -200~1800℃
4. Explosion-proof form: explosion-proof enclosure.

Executive standard

GB/T30429-2013

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
WSSN Radial Bimetal Seismic Thermometer

4 sku

WSSN Radial Bimetal Seismic Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: -50~600℃, customized.
6. Filling fluid: silicone oil (default), glycerin, fluorinated oil, or propylene glycol, optional.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
Regular Temperature Transmitter

1 sku

Regular Temperature Transmitter

Technical parameters

1. Input: Thermocouple K-type, E-type, B-type, S-type, T-type, J-type, N-type RTD Pt100 Cu100 Cu50 (three-wire or four-wire system)
2. Output: Output 4~20ma DC signal within the range. Linear with the millivolt signal input by thermocouple; linear with the input resistance signal of the RTD. Or linear with temperature signal. As an isolation temperature transmitter, input and output phases are isolated with isolation voltage of 0.5KV, increasing resistance to common-mode interference, more suitable for use with computer networking.
3. Basic error: *±0.5% F・S
4. Transmission method: two-wire system
5. Display mode: (digital) LCD four-bit display, show a sign of e ... when open circuit of thermocouple occurs with output greater than 20mA
6. Working power: Min. voltage of transmitter working power is 12V, Max. voltage 35V, rated operating voltage 24V.
7. Load: Limit load resistance is calculated as follows:
RL (max)=50 (Vmin-12) (i.e. at 24V,
load resistance can be selected within 0~600Ω)
Rated load 250Ω.
8. Normal operating environment:
a) Ambient temperature: -25°C~80°C (Regular type)
-20°C~70°C (Digital display type)
b) Relative humidity: 5%~95%
c) Mechanical vibration: f≤50hz, amplitude <0.15mm
d) In ambient air, there is no corrosive medium for chromium, nickel coating, non-ferrous metals
and other alloys.
9. Impact of ambient temperature: ≤0.05/1°C
Note: "*" Contracted products with a tolerance error of ±0.2% can be provided if specially requested by customers.
10. Mount: regular type, dedicated type, wall mounted type and guide rail type

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
Anti-wear thermocouple

1 sku

Anti-wear thermocouple

Technical parameters

1.Electrical outlet: M20×1.5, NPT1/2.
2. Anti-wear head hardiness: HRC62 ~ 65.
3. Protection class: lP65.

Executive standard

Company standard

Supply capability

Brand : CAHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Fixed flange-type explosion-proof thermocouple with temperature transmitter

1 sku

Fixed flange-type explosion-proof thermocouple with temperature transmitter

Technical parameters

1. Measuring temperature: -200℃~1300℃;

Executive standard

IEC584 IEC751 JB/T5518-1991 JB/T7391-1994

Supply capability

Brand : CAHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Flexible-pipe joint-type thermocouple

1 sku

Flexible-pipe joint-type thermocouple

Technical parameters

1. Measuring Temperature: 0~1000℃;

Executive standard

IEC584 JB/T9238-1999

Supply capability

Brand : CAHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Furnace wall thermocouple

1 sku

Furnace wall thermocouple

Technical parameters

1.Accuracy class: Class I and II.
2.Nominal pressure: normal pressure.
3.Bending radius: R ≥ 5D.

Executive standard

Company standard

Supply capability

Brand : CAHE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Guide rail temperature transmitter

1 sku

Guide rail temperature transmitter

Technical parameters

1. Input: Thermocouple K-type, E-type, B-type, S-type, T-type, J-type, N-type RTD Pt100 Cu100 Cu50 (three-wire or four-wire system)
2. Output: Output 4~20ma DC signal within the range. Linear with the millivolt signal input by thermocouple; linear with the input resistance signal of the RTD. Or linear with temperature signal. As an isolation temperature transmitter, input and output phases are isolated with isolation voltage of 0.5KV, increasing resistance to common-mode interference, more suitable for use with computer networking.
3. Basic error: *±0.5% F・S
4. Transmission method: two-wire system
5. Display mode: (digital) LCD four-bit display, show a sign of e ... when open circuit of thermocouple occurs with output greater than 20mA
6. Working power: Min. voltage of transmitter working power is 12V, Max. voltage 35V, rated operating voltage 24V.
7. Load: Limit load resistance is calculated as follows:
RL (max)=50 (Vmin-12) (i.e. at 24V,
load resistance can be selected within 0~600Ω)
Rated load 250Ω.
8. Normal operating environment:
a) Ambient temperature: -25°C~80°C (Regular type)
-20°C~70°C (Digital display type)
b) Relative humidity: 5%~95%
c) Mechanical vibration: f≤50hz, amplitude <0.15mm
d) In ambient air, there is no corrosive medium for chromium, nickel coating, non-ferrous metals
and other alloys.
9. Impact of ambient temperature: ≤0.05/1°C
Note: "*" Contracted products with a tolerance error of ±0.2% can be provided if specially requested by customers.
10. Mount: regular type, dedicated type, wall mounted type and guide rail type

Executive standard

QB

Supply capability

Brand : HENGHE

Guarantee period : 12 months

Enquiry Now
WSSN Axial Bimetal Seismic Thermometer

4 sku

WSSN Axial Bimetal Seismic Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: -50~600℃, customized.
6. Filling fluid: silicone oil (default), glycerin, fluorinated oil, or propylene glycol, optional.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now
WSS Radial Bimetal Thermometer

4 sku

WSS Radial Bimetal Thermometer

Technical parameters

1. Casing: 65, 80, 100, 150mm, optional;
2. Temperature sensing probe diameter: 6.35, 8, 10mm, optional;
3. Temperature sensing probe length: 50 mm the shortest, customized;
4. Indicator dial: aluminum, black characters on a white background.
5. Range: - 50 ~ 600℃, can be customized.

Executive standard

JB/T8803-2015

Supply capability

Brand : LEAGOO

Guarantee period : 12 months

Enquiry Now