LA5817 Series Explosion-proof Electric Hoist Button

1 sku

LA5817 Series Explosion-proof Electric Hoist Button

Technical parameters

1. Explosion-proof sign: ExdIIBT6;
2. Rated voltage: AC380v/220V/50HZ;
3. Rated current: 10A;
4. Protection grade: IP65;
5. Corrosion-proof level: WF2;
6. Thread specification at inlet: G3/4′′ inlet specification;
7. Cable specification: suitable for cable of Ф10mm ~ Ф14mm.

Executive standard

GB3836-2000/IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
BCX8030 series explosion-proof anti-corrosion lighting power distribution box

10 sku

BCX8030 series explosion-proof anti-corrosion lighting power distribution box

Technical parameters

1. Execution standard: GB3836-2000 IEC60079;
2. Explosion-proof sign: EXdII CT6;
3. Rated voltage: 380/220;
4. Rated current of branch (A): 63;
5. Number of branches: 4, 6, 8, 10, 12;
6. IP grade: IP55;
7. Corrosion-proof level: WF2.

Executive standard

GB3836-2000 IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
BLK52 explosion-proof circuit breaker

1 sku

BLK52 explosion-proof circuit breaker

Technical parameters

1. Rated voltage: 220V, 380V;
2. Tripping current: 1A~630A;
3. Explosion-proof sign: Exde II BT6, Exde II CT6;
4. Cable outer diameter: 14-50 mm.

Executive standard

GB3836-2000 IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
BLK8050 (8060) series explosion-proof anti-corrosion circuit breaker

2 sku

BLK8050 (8060) series explosion-proof anti-corrosion circuit breaker

Technical parameters

1. Execution standard: GB3836-2000 IEC60079;
2. Explosion-proof sign: EXdeIICT6;
2. Rated voltage: AC380v/220V;
4. Release current rating (A): 1, 3, 6 (5), 10 16 (15), 20, 25, 32, 40, 50, 63 (60);
5. Protection grade: IP55;
6. Corrosion-proof level: WF2;
7. Outer diameter of the cable (mm): 14-17, 18-26;

Executive standard

GB3836-2000 IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
LBQC explosion-proof electromagnetic starter

1 sku

LBQC explosion-proof electromagnetic starter

Technical parameters

1. Executive standards: GB3836.1, GB3836.2, GB3836.3, GB12476.1, IEC60079;
2. Explosion-proof sign: ExdeIIBT6, ExdeIICT6, DIP A20 Ta, T6;
3. Rated voltage: AC 380V;
4. Rated current: 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A;
5. Use category: AC-3;
6. Protection level: (IIB), IP55 (IIC), IP65 (DIP);
7. Corrosion-proof level: WF1;
8. Installation method: hanging.

Executive standard

GB3836.1、GB3836.2、GB3836.3、GB12476.1、IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
BQJ51 Series Explosion-proof Self-adjusting Voltage-releasing Starter

1 sku

BQJ51 Series Explosion-proof Self-adjusting Voltage-releasing Starter

Technical parameters

1. Execution standard: GB3836-2000 IEC60079;
2. Explosion-proof sign: EXdIIBT4;
3. Rated voltage: AC380v/50HZ;
4. Use class: AC-3\AC-4;
5. Protection grade: IP54;
6. Corrosion-proof level: WF1;
7. Inlet specification: G1 1/2”-G3”;  
8. Outlet specification: G1 1/2”-G3”;  
9. Cable specification: Ф17mm-Ф55mm.

Executive standard

GB3836-2000 IEC60079

Supply capability

Brand : IRE

Guarantee period : 12 months from the date of delivery

Enquiry Now
Single-core Aluminum 26/35KV Cross-linked Polyethylene Insulated Thick Steel Wire Armored PVC Sheathed Power Cable

2 sku

Single-core Aluminum 26/35KV Cross-linked Polyethylene Insulated Thick Steel Wire Armored PVC Sheathed Power Cable

Technical parameters

1. The maximum rated operating temperature of the cable conductor is 90°C;
2. The maximum operating temperature of the cable conductor does not exceed 250°C in short-circuit (maximum duration within 5s);
3. The ambient temperature during cable laying shall be no lower than 0°C. If it is laid below 0°C, it must be warmed in advance;
4. Allowable bending radius for cable installation:
Single core cable: not armored R=20D and armored R=15D; multi-core cable: not armored R=15D and armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
Single-core Copper 0.6-1KV PVC Insulated PVC Sheathed Power Cable

2 sku

Single-core Copper 0.6-1KV PVC Insulated PVC Sheathed Power Cable

Technical parameters

1. Rated voltage 0.6/1KV;
2. Maximum temperature of cable conductor: 70℃ for PVC insulated, 90℃ for cross-linked polyethylene insulated;
3. The maximum temperature of cable conductor during short-circuit (maximum duration no more than 5S) shall not exceed: PVC insulated conductor cross-section ≤300mm2, 160°C, PVC insulated conductor cross-section> 300mm2, 140°C; Cross-linked Polyethylene insulation 250 °C;
4. Laying temperature of cables: The laying temperature of cables with PVC insulation or sheath shall not be lower than 0°C;
5. Allowable bending radius for cable installation:
Single-core cable non-armored R=20D, armored R=15D
Multi-core cable non-armored R=15D, armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
Three-core Copper 26/35KV Cross-linked Polyethylene Insulated Polyethylene Sheathed Power Cable

2 sku

Three-core Copper 26/35KV Cross-linked Polyethylene Insulated Polyethylene Sheathed Power Cable

Technical parameters

1. The maximum rated operating temperature of the cable conductor is 90°C;
2. The maximum operating temperature of the cable conductor does not exceed 250°C in short-circuit (maximum duration within 5s);
3. The ambient temperature during cable laying shall be no lower than 0°C. If it is laid below 0°C, it must be warmed in advance;
4. Allowable bending radius for cable installation:
Single core cable: not armored R=20D and armored R=15D; multi-core cable: not armored R=15D and armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery

Enquiry Now
Single-core Aluminum 21/35KV Cross-linked Polyethylene Insulated Thin Steel Wire Armored PVC Sheathed Power Cable

2 sku

Single-core Aluminum 21/35KV Cross-linked Polyethylene Insulated Thin Steel Wire Armored PVC Sheathed Power Cable

Technical parameters

1. The maximum rated operating temperature of the cable conductor is 90°C;
2. The maximum operating temperature of the cable conductor does not exceed 250°C in short-circuit (maximum duration within 5s);
3. The ambient temperature during cable laying shall be no lower than 0°C. If it is laid below 0°C, it must be warmed in advance;
4. Allowable bending radius for cable installation:
Single core cable: not armored R=20D and armored R=15D; multi-core cable: not armored R=15D and armored R=12D
R: minimum bending radius, D: cable outside diameter.

Executive standard

Company standard

Supply capability

Brand : WANDA

Guarantee period : One year from the date of delivery